Showing results: 16 - 30 of 35 items found.
-
FT-2500 -
Ono Sokki
FT-2500 advanced tachometer measures the rotational speed by using the signal of change in sound, vibration or magnetic flux from rotating machines such as motor or the like.The use of FFT technology enables the FT-2500 to calculate and display the rotational speed of any complex waveform signals from microphone, sound level meter or vibration sensor by extracting the frequency component which is equivalent to the rotational speed.
-
FT-7200 -
Ono Sokki
The FT-7200 Advanced Tachometer is an easy-to-use handheld digital tachometer offering high functions and performance. The use of FFT (Fast Fourier Transform) technology enables the FT-7200 to perform frequency analysis of rotation speed by using change of signal in sound, vibration or magnetic flux from rotating machines such as a motor or the like. Selection from 5 kinds of measurement modes allows it to calculate and display rotation speed of any complex waveform signals from a sound level meter or an accelerometer accurately by extracting the exact frequency component.
-
Model 2100 -
Magnetic Instrumentation Inc.
The Model 2100 Gaussmeter is a fully featured, high-end Gaussmeter with a low cost Gaussmeter price. It is a compact, high accuracy, microprocessor controlled, flux density measuring instrument. The Model 2100 is capable of measuring static (DC), alternating (AC), or pulsed magnetic fields. Twelve measurement ranges allow the operator to configure the meter for maximum resolution and accuracy from 300mG (30 microTesla) to 300 kG (30 Tesla). Selecting primary measurement functions is quick and easy with dedicated front panel function keys. An easy-to-use menu allows access to user defined parameters such as upper and lower magnetic limits and relative magnetic measurements. Remote meter configuration is completely accessible using the built in RS-232 Interface or optional IEEE-488 Interface.
-
TRF -
TOEI INDUSTRY CO, LTD.
Low drift makes it possible to easily adjust Automatic recording of magnetization curves in high sensitivity and at high speed and yet in high accuracy. Depending on kind of measured sample, models are classified into special for hard magnetic materials, for soft magnetic materials, and for both hard and soft magnetic materials.
-
ChenYang Technologies GmbH & Co. KG
A Fluxmeter is an electronic integrating, digital display instrument. The Fluxmeter can be used not only for the measurement of the magnetic flux of permanent magnets, but also for quality control and sorting of magnetic products. Its versatility makes the employment possible in laboratory enterprise as also in production.
-
FDI2056 -
Metrolab Technology SA
The Fast Digital Integrator FDI2056 is the world's fastest and most sensitive voltage integrator. Simply plug in a sense coil and measure fast, low-level magnetic field disturbances such as eddy currents in a switched magnet.Equipped with a high-speed Analog-to-Digital Converter (ADC), high-resolution clock, and highly optimized digital integrator, the FDI2056 boasts a maximum of 500 000 partial integrals per second and provides resolutions down to 10-14 Vs with an accuracy of 10 ppm. Magnetometer Fluxmeter
-
F 10 -
Dr. Brockhaus Messtechnik GmbH & Co. KG
For measuring all magnetic properties of magnetic material relevant to quality control. Applications in research and development, automatic process control, quality control, and at incoming inspection.
-
B1 -
MAGMESS Magnet-Messtechnik
Battery powered handheld fluxmeter using two measuring ranges and attenuator from 10-100%. With digital LCD-display, analog output 0-200 mV. Possibility to connect a foot switch for the reset function.
-
FG16 -
MAGSYS Magnet Systeme GmbH
The fluxmeter FG16 is a modular device to measure magnetic values and can be equipped with up to 4 channels. The completely redesigned analog-/digital-hybrid design of the fluxmeter plug-in allows measurements of both high-dynamic as well as very fast events and is virtually drift-free.
-
B2 -
MAGMESS Magnet-Messtechnik
Electronic integrator of high sensitivity and very low drift. Equipped with USB interface, maximum/minimum store and comparator. 4 Measuring ranges. Constants of measuring from 10 E-7 to 10 E-4 Vs/digit. Attenuator from 10-100%. Digital 3 ½ digit LED-display and analog output 0-200 mV. Possibility to connect a foot switch for the reset function. Input: Ri = 10 kOhm.
-
B3 -
MAGMESS Magnet-Messtechnik
Electronic integrator of high sensitivity and extremely low drift. Equipped with RS 232 interface, maximum minimum store and comparator. 4 measurement ranges. Constants of measuring ranging from 10E-7 Vs/digit to 10E-4 Vs/digit.
-
Hirst Magnetic Instruments Ltd
Fluxmeters for advanced measurements a Fluxmeter can be used to measure Magnetic Flux Linkage where a surface reading with a Gaussmeter is not sufficient.
-
WB10 -
R&J Measurement
The WB10 Fluxmeter is designed to measure the change of magnetic flux in measurements of magnetic properties of the magnetic materials in quasi-static and slowly floating conditions. Fluxmeter is the electronic measuring device with high sensitivity, very small drift as well as very small error of integration in a long time.
-
DX-201 -
Dexing Magnet Tech. Co., Ltd
DX-201 digital fluxmeter is a precise magnetic measuring instrument, adopted low drift electronic integrator design and production. The most important features are test response quick, without data lose in the testing process. In the process of test samples flux by the Czochralski method, fast pull and slow pull datas are consistent, fine features especially shows in repeated measurements and regression testing. It can measure magnetic flux or magnetic moment matched with different fixtures according to users’ requirements.
-
480 -
Lake Shore Cryotronics, Inc.
An advanced tool designed primarily for use in industrial and measurement systems settings, the Model 480 Fluxmeter measures total flux from which B, flux density, and/or H, magnetic field strength, can be determined. The Model 480 is valuable for magnetizing, manual and automated magnet testing and sorting, and as the main component in BH loop or hysteresis measurement system applications.